Find Bio Fuel Generator, Double Fuel Generator, Dual Fuel Engine on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Duel Fuel Generator > 50Hz Googol 1000kW Nature Gas Diesel Double Fuel Generating set

50Hz Googol 1000kW Nature Gas Diesel Double Fuel Generating set

Basic Info

Model No.: HG series

Product Description

50Hz Googol 1000kW Nature Gas Diesel Double Fuel Generating set  
Dual Fuel genset Model   HDGM1400
Genset Standby Power kW/kVA 1120/1400
Genset Prime Power kW/kVA 1000/1250
Genset Continuous Power kW/kVA 900/1125
Rating Voltage V 400
Rating Frequeny Hz 50
Rating Power Factor   0.8
Rating Prime Current A 1800
Speed  rpm 1500
Engine Model   QTA3240-BG1
Speed  rpm 1500
Frequency  Hz 50
 Rating Output    
Engine Standby Output (LTP) kW 1247 
Engine Prime Output (PRP) kW 1121 
Engine Continuous Power (COP) kW 970 
Basic Performance Datasheet    
Aspiration Type   Turbocharger, air-water aftercooler
Injection Type   Direct Injection
Configuration   Vee
No. of Cylinders   12
Displacement  l 53.1
Bore  mm 170
Stroke  mm 195
Compression Ratio   13.5:1
Cooling System    
Coolant Capacity for Engine  l 100
Radiator Cooling Flow   m³/min 2120
Flow of Coolant pump  m³/h 48+45
Fuel &Gas System    
Governor Type   Electrical 
Engine Output at genset prime output kW 1121 
Fuel &gas Consumption at 100% of genset prime output l/h 77.46
Intake & Exhaust System    
Combustion Air Consumption  m³/min 106.32
Max. Intake Restriction  KPa 2
Max. Exhaust Temperature (After Turbo) °C 415
Max. Exhaust Back Pressure  KPa 2
Exhaust Gas Flow   m³/min 269.05 
Engine Dimension    
Length  mm 3096
Width  mm 1459
Height  mm 1820
Engine Dry Weight w/o Cooling System kg 5200
  Applied gas: Natural Gas,  Acceptable fuel gas pressure: 5~12kPa CH4 content: for natural gas≥85% CH4 ,content:for biogas≥40% Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency. Gas doesn’t include free water or free materials (the size of impurities should be less than 5μm.) H2S content≤200mg/Nm³ NH3 content≤20mg/Nm³ Impurities content≤30mg/Nm³;size≤5μm Water content≤40g/Nm³, no free water.   Acceptable working conditions: Ambient temperature : -10°C~+40°C  (antifreeze or preheater needed for below 0°C) Relative humidity:<90%(20°C) Altitude:≤1000m Normal working conditions: Genset can run at rated power on the conditions: Atmospheric Pressure: 100kPa, Ambient Temp: 20°C, Relative Humidity: 30%.     Performance Feature Engine and alternator shall be mounted on a same frame steel skid.   Built-in damper for anti-vibration. World most famous brand diesel engine. World famous brand AC alternator. Advanced and reliable control module Full range protection function and alarm shutdown feature.    Alternator Feature Brush-less, 4 poles, rotation magnet. IP21-23(NEMA1) enclosure is standard for all industrial alternators. The insulation system is Class H Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts. Wide range of flange adaptors and single bearing disc coupling. Standard 2/3 pitch windings avoid excessive neutral currents AVR auto voltage regulator, auto exciter, auto adjustment    Standard Accessory  Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery and connecting wires, Operation manual and document.    Optional Accessory Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & paralleling system, and Moving Trailer.   Silent Canopy Description Standard Accessory: Steel Weatherproof Canopy Built In Fuel Tank For 8 Hours Running Built In Control Panel Built In Start Battery Power Output Rapid Insert  Windows for Looking Air Louver for Intake & Exhaust Exhaust Gas Silencer Soundproof Type   Quality Warranty Period:  All equipment is guaranteed for a period of 1000 hours running or 12 months from the date when the generator set has been delivered from the factory.   ATS SYSTEM      For emergency power usage in building, Auto transfer switch (ATS) is essential. ATS can automatic transfer load from Mains power supplying to Emergency power. In normal, when the Main power supplying failure or voltage drop below 80% of normal voltage, ATS will auto start Emergency generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reach at rated speed, the ATS will transfer the load to emergency generator sets automatically.   Generator Engine OEMs:   Generator Alternator OEMs:   Honny Power Certificates:   Honny Power Introduction:

Contact us if you need more details on Bi-fuel Generator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Double-fuel Generating Set、1000kw Generator Set. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Duel Fuel Generator