Reserve Battery Power Plant 12V1.2AH
Basic Info
Model No.: FP1212
Product Description
Specially designed deep-cycle cells are much less susceptible to degradation due to cycling, and are required for applications where the batteries are regularly discharged, such as photovoltaic systems, electric vehicles (forklift, golf cart, electric cars and other) and uninterruptible power supplies. These batteries have thicker plates that can deliver less peak current, but can withstand frequent discharging.
can be used for just about every application, including: UPS Backup Systems, Alarm Systems, Fire Alarm Systems, Medical Equipment, Test Equipment, and much more.
Specifications
Nominal Voltage | 12 V | ||
Capacity (25℃) | 20HR(10.5V) | 1.2Ah | |
10HR(10.5V) | 1.12Ah | ||
1HR(9.60V) | 0.78Ah | ||
Dimension | Length | 97±1mm (3.82inch) | |
Width | 43±1mm (1.69inch) | ||
Height | 52±1mm (2.05inch) | ||
Total Height | 58±1mm (2.28inch) | ||
Approx. Weight | 0.54kg (1.19lbs)±5% | ||
Terminal type | T1 | ||
Internal resistance (Fully charged, 25℃) | Approx. 90mΩ | ||
Capacity affected by temperature (20HR) | 40℃ | 102% | |
25℃ | 100% | ||
0℃ | 85% | ||
-15℃ | 65% | ||
Self-discharge (25℃) | 3 month | Remaining Capacity: 91% | |
6 month | Remaining Capacity: 82% | ||
12 month | Remaining Capacity: 65% | ||
Nominal operating temperature | 25℃±3℃(77℉±5℉) | ||
Operating temperature range | Discharge | -15℃~50℃(5℉~122℉) | |
Charge | -10℃~50℃(14℉~122℉) | ||
Storage | -20℃~50℃(-4℉~122℉) | ||
Float charging voltage(25℃) | 13.60 to 13.80V Temperature compensation: -18mV/℃ | ||
Cyclic charging voltage(25℃) | 14.50 to 14.90V Temperature compensation: -30mV/℃ | ||
Maximum charging current | 0.36A | ||
Terminal material | Copper | ||
Maximum discharge current | 18A(5 sec.) | ||
Designed floating life(20℃) | 10years | ||
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
|
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME | 5min | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 10h | 20h |
9.60V | 4.56 | 2.88 | 2.28 | 1.27 | 0.78 | 0.43 | 0.306 | 0.245 | 0.208 | 0.113 | 0.061 |
9.90V | 4.42 | 2.79 | 2.23 | 1.25 | 0.77 | 0.42 | 0.304 | 0.243 | 0.207 | 0.113 | 0.061 |
10.2V | 4.24 | 2.68 | 2.14 | 1.21 | 0.75 | 0.42 | 0.302 | 0.242 | 0.205 | 0.112 | 0.060 |
10.5V | 4.06 | 2.56 | 2.07 | 1.18 | 0.73 | 0.41 | 0.300 | 0.240 | 0.204 | 0.112 | 0.060 |
10.8V | 3.83 | 2.42 | 1.96 | 1.14 | 0.71 | 0.40 | 0.291 | 0.233 | 0.198 | 0.109 | 0.059 |
Constant Power Discharge Characteristics (Watt, 25℃)
F.V/TIME | 5min | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 10h | 20h |
9.60V | 50.9 | 32.5 | 26.0 | 14.6 | 9.0 | 4.99 | 3.64 | 2.92 | 2.48 | 1.36 | 0.73 |
9.90V | 49.4 | 31.5 | 25.4 | 14.3 | 8.9 | 4.96 | 3.61 | 2.90 | 2.47 | 1.35 | 0.73 |
10.2V | 47.3 | 30.2 | 24.4 | 13.8 | 8.7 | 4.91 | 3.59 | 2.88 | 2.45 | 1.35 | 0.72 |
10.5V | 45.3 | 28.9 | 23.6 | 13.5 | 8.5 | 4.84 | 3.56 | 2.86 | 2.44 | 1.34 | 0.72 |
10.8V | 42.7 | 27.3 | 22.4 | 13.0 | 8.2 | 4.72 | 3.46 | 2.77 | 2.36 | 1.31 | 0.71 |
Note: The above characteristics data can be obtained within three charge/discharge cycles.
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
FP Series Battery General Features
- Nonspillable
- Sealed and Maintenance-free Operation
- High Quality and High Reliability
- Exceptional Deep Discharge Recovery
- Low Self-discharge
- Long Service Life
- Solid Copper Terminals
- Tank-formed Plates
- Computer-aided Design and Manufacturing
- UL, CE, VdS Approved
Typical Applications
- Telecommunication equipment
- Electronic instruments
- Fire alarm
- Security devices
- UPS power supply
- Emergency lighting
Product Categories : Network Power/Reserve Battery > Standard Series Battery